Uncertainty Evaluation and Analysis of D 50 Parameters of Atomized

SHI Ling, HAN Shuyong, YANG Chengwu,CHEN Wen   

  1. Hubei Key Laboratory of Industrial Fume and Dust Pollution Control, School of Chemistry and Environmental Engineering,Jianghan University, Wuhan 430056, Hubei, China
  • Online:2014-12-25 Published:2014-12-26

Abstract: Nozzle is widely applied in the devices of wet desulphurization,dust removal and others ,the D50 of the atomized droplets is the key parameter to evaluate the nozzle. Atomization experiments of different pressure and distance for the nozzle with the apertures of 1 . 44 μm and 0 . 46 μm were carried on ,and the uncertainty values of the D50 of the atomized droplets are calculated with uncertainty evaluation method. The experiment and evaluation results indicate,the D50 value of the atomized droplets changes a lot with the change of atomized conditions ,but the deviation of the D50 values inthe same conditions is small with the maximum value of measure of uncertainty being 5 μ m.And the further conclusion is that the D50 of the atomized droplets is determined by the structure of nozzle,and it is reliable to guide these lection of nozzle with D50.

Key words: D 50, atomizeddroplet, uncertaintymeasurement, sprayingnozzle